FS 60mm 8009230 TC Xylem Flygt Mechanical Seals 80mm For Manifold
Model | FS XE | Specilcation | Shaft Hole 20-80mm |
---|---|---|---|
Material | TC TC TC TC | Usage | Manifold |
Traemark | Bergman | Origin | Guangzhou, China |
High Light | 60mm Flygt Mechanical Seals,80mm Flygt Mechanical Seals,Flygt Manifold Seals |
FS 60mm 8009230 TC Xylem Flygt Mechanical Seals 3202 4670 4680 7030 5100
Xylem Flygt Pump FS-60mm 8009230 Mechanical Seal 3202 4670 4680 7030 5100
Flygt Pump FS-60mm 8009230 Mechanical Seal 3202 4670 4680 7030 5100-300 5100-310 5150-300 5150-310 Sewage Pump Seal Manufacturer Excellent Quality Industry Leading Spot Supply
Basic Info.
The seals and basic repair kits for Xylem Flygt equipment are simpler, easier to install, and more robust than the OEM seals.
The rubber color could be black, brown or green.
Features: Double mechanical seal in a single unit assembly
Seal faces remain protected from contamination
Springs are protected from corrosive pump media and clogging
Inner and outer seals are replaced at the same time,ensuring overall sealing reliability
Flygt Pump Model | ShaftSize | upper Seal | Lower Seal |
3085-091,3085-120.3085-170,3085-171,3085- 181,3085-280,3082-290,3085-890 |
20mm | Fs-G-U20 | FS-G-L20 0r FS-H-L20 |
3101 | 28mm | FS-B-U28 | FS-B-L28 |
3102 | 25mm | FS-J-U25 | FS-J-L25 |
3126-90,3126-180 | 35mm | FS-K-U35 | FS-K-L35 |
3126-91,3126-280,3126-290 | 35mm | FS-K-u35 | FS-M-L35 |
3126-181,3127 | 35mm | FS-M-U35 | FS-M-L35 |
3140,3152 | 45mm | FS-O-U45 | FS-O-L45 |
3170,3201 | 60mm | Fs-Q-u60 | FS-Q-L60 |
3200 | 60mm | FS-P-U60 | FS-P-L60 |
3230,3300-91.3300-181,3300-280, 3300-9B0,3305 |
90mm | FS-s-u90 | FS-S-L90 |
3310.3311,3312,3350,3351 | 90mm-120mm | FS-s-u90 | FS-T-L120 |
3355.3356,3357 | 90mm | FS-s-u90 | FS-s-L90 |
3,500,350,135,303,530,000,000,000,000 | 90mm-120mm | Fs-s-u90 | FS-T-L120 |
4351.4352,4400 | 20mm | Fs-G-u20 | FS-H-L20 |
4410,4430 | 60mm | FS-Q-L60 | |
4440,5530 | 35mm | FS-M-U35 | FS-M-L35 |
46,504,660 | 45mm | Fs-O-u45 | FS-O-L45 |
4670,4680,7045 | 60mm | FS-Q-u60 | FS-Q-L60 |
7050.7051.7055,7060,7061,7076.7556 | 90mm | FS-s-u90 | Fs-s-L90 |
7080,7115 | 90mm-80mm/90mm~120mm | FS-s-u90 | FS-S-L80/FS-T-L120 |
7570,7585 | s0mm-120mm | FS-s-u90 | FS-T-L120 |
Grindex Mai0r,Master,Matad0r,Midi,Minette,Salvad0r | 25mm~24mm | FS-Z-U25 | FS-Z-L24 |
Grindex Maxi | 45mm | FS-O-u45 | FS-N-L45 |
Ready m0dels 4 8 12&16 | 15mm | FS-D-U15 | |
Ready 24 | 20mm | FS-A-U20 | FS-A-L20 |
Ready 90 | 28mm | FS-1-u28 | FS-1-L28 |
Steaty 7 | 20mm | FS-G-u20 | FS-G-L20 |
600 | 60mm | FS-Q-u60 | FS-O-L60 |
605,615.665.670,680 | 90-80mm | Fs-s-u00 | FS-s-L80 |
705.715.720.721,735,745,760,765.770.775 | 90mm~80mm/90mm~120mm | FS-s-u90 | FS-S-L80/FS-T-L120 |
820,840,841.860,880,881,900 | 90mm-80mm/90mm~120mm | FS-s-u90 | FS-S-L80/FS-T-L120 |
2004,2008,2012,2016 | 15mm | FS-D-U15 | |
2024 | 20mm | FS-A-U20 | FS-A-L20 |
2050,2052 | 15mm | FS-D-U15 | , |
2060 | 20mm | FS-G-u20 | FS-G-L20 |
2066 | 20mm | FS-A-U20 | FS-A-L20 |
2070 | 22mm | FS-E-U22 | FS-E-L22 |
2071 | 22mm | FS-E-U22 | FS-E-L22 |
2075 | 20mm | FS-A-U20 | FS-A-L20 |
2082,2090,2125,2140 | 28mm | FS-1-U28 | FS-1-L28 |
2084,2135 | 35mm | FS-K-u35 | FS-K-L35 |
2i01 | 20mm | FS-A-U20 | FS-A-L20 |
2102-40 | 22mm | FS-E-U22 | FS-E-L22 |
2151-10 | 35mm | FS-K-U35 | FS-K-L35 |
2151-11,2151-50 | 35mm | FS-K-U35 | FS-L-L35 |
2201-10,2201-320,2201-430,2201-480 | 45mm-35mm | FS-O-U45 | FS-K-L35 |
2201-590.2201-690 | 45mm | Fs-O-u45 | FS-O-L45 |
2201-11HT 0r MT | 45mm | FS-N-U45 | FS-N-L45 |
2201-11LT | 45mm | FS-O-u45 | FS-N-L45 |
2250,2290 | 60mm | FS-P-U60 | FS-P-L60 |
2400 | 60mm | FS-R-U60 | FS-R-L60 |
3041-281 | 20mm | FS-G-u20 | FS-G-L20 |
3057 | 20mm | FS-G-u20 | FS-H-L20 |
3057-180,3060 | 20mm | FS-G-u20 | FS-G-L20 |
3085 | 20mm | FS-A-U20 | FS-A-L20 |
3067-170,3067-250,3068 | 20mm | Fs-G-u20 | FS-G-L20 |
3080 | 20mm | FS-A-U20 | FS-A-L20 |
3082_ | 22mm | FS-E-u22 | FS-E-L22 |
We have used Xylem, Flygt, Rovala, a full range of water pumps, mechanical seals, and real shots of products.
Fixing and Applying Directions of Mechanical Seals
1. Select Appropriate mechanical seal to match the materials according to work conditions and host machine equipment.
2. The radial acting deviation for the shaft(shaft sleeve) of the installed mechanical seal shall be 0.04mm by maximum
while the axial movement value of the rotor shall be no more than 0.1mm.
3. The seal cover (or shaft cover) of the stationary ring of the installed mechanical seals,the vertical degree of the seal
face should be 0.04mm by maximum.
4. When installing the mechanical seals,the shaft(shaft sleeve),seal chamber,seal face as well as the mechanical seal
must be cleaned in order to keep from any medium to sealing part.
5. When conveying medium of over high or low temperature,with medium which are easy catch fire,easy for explosion.
Related mechanical seal standards must be referred to take appropriate measures such as quench,rinsing,coolong and
filtrating.
6. Appropricate lubrication must be choosen when mechanical seal is installed.The installment size of the mechanical
seal must be guaranteed to the installment instruction.
7. Before the machine starts running,the hermetic compartment shall be full of medium and well lubricated.Dry friction
which may lead to the damage of the air-tightness is strict forbidden.